Monday, May 6, 2024

2024 National Safety Stand-Down To Prevent Falls in Construction

 OSHA's National Fall Prevention Safety Stand-Down Week! (5/6/24 - 5/10/24)

Today is the start of OSHA's National Fall Prevention Safety Stand-Down Week.  This is OSHA's 11th year of holding the Stand-Down and IDI has participated in this since its inception.  OSHA's goal of the Stand-Down is to raise fall hazard awareness and to prevent fall fatalities and injuries.  Falls are the #1 leading cause of death for construction workers accounting for 397 out of 1069 in 2022.  IDI will be participating in the fall prevention stand-down again this year.  The founder of IDI, Tony Pintozzi Sr., opened the doors of the company in 1952 (72 years ago) and ever since IDI was established, we have never had a fall related fatality.  In fact, IDI has never had a work related fatality and is something that Tony and the current leaders of the company are very proud of as this shows what our safety culture is all about.

The following is how IDI will be participating in the Stand-Down.  On Wednesday, 5/8/24, we need for our lead field supervisors & PCLs to gather your crews together during your normal morning tasked based safety awareness huddle and we want everyone performing the same toolbox talk. For your reference that Toolbox talk is attached to this email. The toolbox talk to perform is from is in SiteDocs – Resources – Toolbox Talks - Fall Protection – What is Fall Protection TBT

During this session, advise our employees that the purpose of this toolbox talk session is for our participation in OSHA's National Fall Prevention Safety Stand-Down.  We are taking a time out for safety and recognizing that falls from elevations are a serious matter.  During this session, we are looking for all employees to participate.  Ask employees if they have ever witnessed a fall at a construction site, and if so, what was that like and what affect it had on them.  Ask if they know of anyone who has sustained a serious fall and again, discuss the affects it had on them, the affects it had on the victim's loved ones.  All employees should be sharing fall protection stories, safety tips and fall prevention related thoughts.  Also, many of the general contractors at the projects we are working at this week will be holding Fall Prevention Stand-Downs and we need for our employees to participate in those. For more information, here is a link to a great Fall Protection Video released by Werner for the 2024 National Stand Down campaign. https://www.youtube.com/watch?v=dEdf9yYZq5g 

Falls from elevations are a serious matter and we need to take them seriously.  This Fall Prevention Stand-Down fits right in with our safety culture and our safety mission statement:  "Everyone Goes Home Alive And In The Same Condition As They Arrived; Your Loved Ones Count On It! 

We want to participate in this Stand-Down because we care about you!  You are part of the IDI family and family looks out for each other.  If you have any questions about this Stand-Down, please contact our Safety Manager Tyler Stark (847) 417-0761.  Have a Safe Day!

Monday, April 1, 2024

Assured Grounding Program - Quarter 2

 

Green Tape on All 3-Pronged Electrical Tools & Extension Cords as of 4/1/2024!

Good morning to all IDI employees:

We begin a new quarter on 4/1/24 for our Assured Grounding Conductor Program. We are to switch over our cords from the previous quarter's white tape to Green tape.  To all PCLs & Lead Field Supervisors, please help keep our employees safe and help keep us OSHA compliant by following our assured grounding conductor program. Please inspect, test and color-code with green tape all extension cords and 3 pronged electrical tools.  All extension cords and tools need to be visually inspected. If you see any defects in the cords such as bare wires, severe kinks, missing or damaged ground prong, the cord pulling away from the plug end-housing, etc., then that tool or cord would need to be immediately removed from service and reported to the lead person. If your tool/cord passes the visual inspection, your next step is to test the cord with a receptacle tester. First, you should test the outlet that you will be plugging your cord into to ensure that it is properly wired. You should see 2 yellow lights lit up on your tester and the red light should be off. This means the outlet is working appropriately. Next, plug your cord into the outlet and then test the cord with the receptacle tester. Again, you should see the same light pattern as mentioned above and this would mean the cord passed the test and it is good and safe to use. Any other light pattern means that there is a problem with the cord and the cord needs to be removed from service and reported to your lead person. If the cord passes the visual inspection and the cord tester test, you should then remove the previous quarter's white electrical tape and install the green electrical tape about 1" down from both plug ends. Your cord is now in compliance with our quarter's Assured Grounding Conductor Program. The green tape shall remain in place from 4/1/24 through 6/30/24. You are not quite done yet! All employees now need to visually inspect all electrical cords and tools on a daily basis and if any defects are found, the cord or tool needs to be immediately removed from service.
Thank you for taking the time to ensure your electrical tools and cords are in safe working order. Your actions may prevent one of our family members from sustaining an electrical shock type injury or worse yet and electrocution. If you need a roll of Green tape, please contact your Superintendent. If you have any questions regarding our Assured Grounding Conductor Program please call our Safety Manager, Tyler Stark at 847-417-0761.
                        !!!HAVE A SAFE DAY!!!

Thursday, December 28, 2023

Assured Grounding Program Quarter 1

 

White Tape on All 3-Pronged Electrical Tools & Extension Cords as of 1/1/2024!

Good morning to all IDI employees:

We begin a new quarter on 1/1/24 for our Assured Grounding Conductor Program. We are to switch over our cords from the previous quarter's Orange tape to White tape.  To all PCLs & Lead Field Supervisors, please help keep our employees safe and help keep us OSHA compliant by following our assured grounding conductor program. Please inspect, test and color-code with green tape all extension cords and 3 pronged electrical tools.  All extension cords and tools need to be visually inspected. If you see any defects in the cords such as bare wires, severe kinks, missing or damaged ground prong, the cord pulling away from the plug end-housing, etc., then that tool or cord would need to be immediately removed from service and reported to the lead person. If your tool/cord passes the visual inspection, your next step is to test the cord with a receptacle tester. First, you should test the outlet that you will be plugging your cord into to ensure that it is properly wired. You should see 2 yellow lights lit up on your tester and the red light should be off. This means the outlet is working appropriately. Next, plug your cord into the outlet and then test the cord with the receptacle tester. Again, you should see the same light pattern as mentioned above and this would mean the cord passed the test and it is good and safe to use. Any other light pattern means that there is a problem with the cord and the cord needs to be removed from service and reported to your lead person. If the cord passes the visual inspection and the cord tester test, you should then remove the previous quarter's orange electrical tape and install the white electrical tape about 1" down from both plug ends. Your cord is now in compliance with our 4th quarter's Assured Grounding Conductor Program. The white tape shall remain in place from 1/1/24 through 3/31/24. You are not quite done yet! All employees now need to visually inspect all electrical cords and tools on a daily basis and if any defects are found, the cord or tool needs to be immediately removed from service.
Thank you for taking the time to ensure your electrical tools and cords are in safe working order. Your actions may prevent one of our family members from sustaining an electrical shock type injury or worse yet and electrocution. If you need a roll of white tape, please contact your Superintendent. If you have any questions regarding our Assured Grounding Conductor Program please call our Safety Manager, Tyler Stark at 847-417-0761.
                        !!!HAVE A SAFE DAY!!!

Thursday, September 28, 2023

Assured Grounding Program Quarter 4

  

Orange Tape on All 3-Pronged Electrical Tools & Extension Cords as of 10/1/23!

Good morning to all IDI employees:

We begin a new quarter on 10/1/23 for our Assured Grounding Conductor Program. We are to switch over our cords from the previous quarter's red tape to Orange tape.  To all PCLs & Lead Field Supervisors, please help keep our employees safe and help keep us OSHA compliant by following our assured grounding conductor program. Please inspect, test and color-code with green tape all extension cords and 3 pronged electrical tools.  All extension cords and tools need to be visually inspected. If you see any defects in the cords such as bare wires, severe kinks, missing or damaged ground prong, the cord pulling away from the plug end-housing, etc., then that tool or cord would need to be immediately removed from service and reported to the lead person. If your tool/cord passes the visual inspection, your next step is to test the cord with a receptacle tester. First, you should test the outlet that you will be plugging your cord into to ensure that it is properly wired. You should see 2 yellow lights lit up on your tester and the red light should be off. This means the outlet is working appropriately. Next, plug your cord into the outlet and then test the cord with the receptacle tester. Again, you should see the same light pattern as mentioned above and this would mean the cord passed the test and it is good and safe to use. Any other light pattern means that there is a problem with the cord and the cord needs to be removed from service and reported to your lead person. If the cord passes the visual inspection and the cord tester test, you should then remove the previous quarter's red electrical tape and install the orange electrical tape about 1" down from both plug ends. Your cord is now in compliance with our 4th quarter's Assured Grounding Conductor Program. The orange tape shall remain in place from 10/1/23 through 12/31/23. You are not quite done yet! All employees now need to visually inspect all electrical cords and tools on a daily basis and if any defects are found, the cord or tool needs to be immediately removed from service.

Thank you for taking the time to ensure your electrical tools and cords are in safe working order. Your actions may prevent one of our family members from sustaining an electrical shock type injury or worse yet and electrocution. If you need a roll of orange tape, please contact your Superintendent. If you have any questions regarding our Assured Grounding Conductor Program please call our Safety Manager, Tyler Stark at 847-417-0761.
                        !!!HAVE A SAFE DAY!!!

Wednesday, June 28, 2023

Assured Grounding Program Quarter 3

 

Red Tape on All 3-Pronged Electrical Tools & Extension Cords as of 7/1/23!

Good morning to all IDI employees:

We begin a new quarter on 7/1/23 for our Assured Grounding Conductor Program. We are to switch over our cords from the previous quarter's green tape to Red tape.  To all PCLs & Lead Field Supervisors, please help keep our employees safe and help keep us OSHA compliant by following our assured grounding conductor program. Please inspect, test and color-code with green tape all extension cords and 3 pronged electrical tools.  All extension cords and tools need to be visually inspected. If you see any defects in the cords such as bare wires, severe kinks, missing or damaged ground prong, the cord pulling away from the plug end-housing, etc., then that tool or cord would need to be immediately removed from service and reported to the lead person. If your tool/cord passes the visual inspection, your next step is to test the cord with a receptacle tester. First, you should test the outlet that you will be plugging your cord into to ensure that it is properly wired. You should see 2 yellow lights lit up on your tester and the red light should be off. This means the outlet is working appropriately. Next, plug your cord into the outlet and then test the cord with the receptacle tester. Again, you should see the same light pattern as mentioned above and this would mean the cord passed the test and it is good and safe to use. Any other light pattern means that there is a problem with the cord and the cord needs to be removed from service and reported to your lead person. If the cord passes the visual inspection and the cord tester test, you should then remove the previous quarter's green electrical tape and install the red electrical tape about 1" down from both plug ends. Your cord is now in compliance with our 3rd quarter's Assured Grounding Conductor Program. The red tape shall remain in place from 7/1/23 through 9/30/23. You are not quite done yet! All employees now need to visually inspect all electrical cords and tools on a daily basis and if any defects are found, the cord or tool needs to be immediately removed from service.

Thank you for taking the time to ensure your electrical tools and cords are in safe working order. Your actions may prevent one of our family members from sustaining an electrical shock type injury or worse yet and electrocution. If you need a roll of red tape, please contact your Superintendent. If you have any questions regarding our Assured Grounding Conductor Program please call our Safety Manager, Tyler Stark at 847-417-0761.
                        !!!HAVE A SAFE DAY!!!

Thursday, March 30, 2023

Assured Grounding Program - Quarter 2

 

Green Tape on All 3-Pronged Electrical Tools & Extension Cords as of 4/1/23!

Good afternoon to all IDI employees:

We begin a new quarter on 4/1/23 for our Assured Grounding Conductor Program. We are to switch over our cords from the previous quarter's white tape to Green tape.  To all PCLs & Lead Field Supervisors, please help keep our employees safe and help keep us OSHA compliant by following our assured grounding conductor program. Please inspect, test and color-code with green tape all extension cords and 3 pronged electrical tools.  All extension cords and tools need to be visually inspected. If you see any defects in the cords such as bare wires, severe kinks, missing or damaged ground prong, the cord pulling away from the plug end-housing, etc., then that tool or cord would need to be immediately removed from service and reported to the lead person. If your tool/cord passes the visual inspection, your next step is to test the cord with a receptacle tester. First, you should test the outlet that you will be plugging your cord into to ensure that it is properly wired. You should see 2 yellow lights lit up on your tester and the red light should be off. This means the outlet is working appropriately. Next, plug your cord into the outlet and then test the cord with the receptacle tester. Again, you should see the same light pattern as mentioned above and this would mean the cord passed the test and it is good and safe to use. Any other light pattern means that there is a problem with the cord and the cord needs to be removed from service and reported to your lead person. If the cord passes the visual inspection and the cord tester test, you should then remove the previous quarter's white electrical tape and install the green electrical tape about 1" down from both plug ends. Your cord is now in compliance with our 2nd quarter's Assured Grounding Conductor Program. The green tape shall remain in place from 4/1/23 through 6/30/23. You are not quite done yet! All employees now need to visually inspect all electrical cords and tools on a daily basis and if any defects are found, the cord or tool needs to be immediately removed from service.

Thank you for taking the time to ensure your electrical tools and cords are in safe working order. Your actions may prevent one of our family members from sustaining an electrical shock type injury or worse yet and electrocution. If you need a roll of green tape, please contact your Superintendent. If you have any questions regarding our Assured Grounding Conductor Program please call our Safety Manager, Tyler Stark at 847-417-0761.
                                   !!!HAVE A SAFE DAY!!!

Thursday, December 29, 2022

White Tape on All 3-Pronged Electrical Tools & Extension Cords as of 1/1/23!

Good afternoon to all IDI employees:

We begin a new quarter on 1/1/23 for our Assured Grounding Conductor Program. We are to switch over our cords from the previous quarter's orange tape to white tape.  To all Safety Advocates & Lead Field Supervisors, please help keep our employees safe and help keep us OSHA compliant by following our assured grounding conductor program. Please inspect, test and color-code with white tape all extension cords and 3 pronged electrical tools.  All extension cords and tools need to be visually inspected. If you see any defects in the cords such as bare wires, severe kinks, missing or damaged ground prong, the cord pulling away from the plug end-housing, etc., then that tool or cord would need to be immediately removed from service and reported to the lead person. If your tool/cord passes the visual inspection, your next step is to test the cord with a receptacle tester. First, you should test the outlet that you will be plugging your cord into to ensure that it is properly wired. You should see 2 yellow lights lit up on your tester and the red light should be off. This means the outlet is working appropriately. Next, plug your cord into the outlet and then test the cord with the receptacle tester. Again, you should see the same light pattern as mentioned above and this would mean the cord passed the test and it is good and safe to use. Any other light pattern means that there is a problem with the cord and the cord needs to be removed from service and reported to your lead person. If the cord passes the visual inspection and the cord tester test, you should then remove the previous quarter's orange electrical tape and install the white electrical tape about 1" down from both plug ends. Your cord is now in compliance with our 1st quarter's Assured Grounding Conductor Program. The white tape shall remain in place from 1/1/23 through 3/31/23. You are not quite done yet! All employees now need to visually inspect all electrical cords and tools on a daily basis and if any defects are found, the cord or tool needs to be immediately removed from service.

Thank you for taking the time to ensure your electrical tools and cords are in safe working order. Your actions may prevent one of our family members from sustaining an electrical shock type injury or worse yet and electrocution. If you need a roll of white tape, please contact your Superintendent. If you have any questions regarding our Assured Grounding Conductor Program please call our Director of Risk, Peter Graham, at (847) 417-1689.

Have a Safe Day!